The Study of Optimal Conditions for the Quantitative Analysis of Silicate Minerals with Electron Probe Micro Analyzer

Authors

  • Sopit Poompuang Department of Geology, Faculty of science, Chulalongkorn University, Bangkok 10330, Thailand

Keywords:

Silicate minerals, Quantitative analysis, Standard reference material, Electron probe micro analyzer

Abstract

The purpose of this study was to determine the optimal operating conditions for the analysis of the main compositions of silicate minerals. These consist of Na2O, Al2O3, FeO, CaO, K2O, P2O5, TiO2, MgO, SiO2 and MnO. The working conditions were designed at 25 nA beam current, 15 and 20 kV acceleration voltage, measurement times of 10, 15, 20, and 30 seconds, and background times of 5 and 10 seconds, respectively. The results showed that the optimum ratio of measurement time to background time for Na2O and Al2O3 was 10:5 seconds; for FeO, CaO and K2O was 10:10 seconds; and for P2O5, TiO2, MgO, SiO2 and MnO was 10:15 seconds. When this optimized condition was analyzed and compared with the standard reference material, the analytical results showed an error of less than 1%, demonstrating that the new condition improved the instrument's measurement efficiency more effectively than the original condition used in the analysis.

References

Batanova, V. G., Sobolev, A. V., & Magnin, V. (2018). Trace element analysis by EPMA in geosciences: Detection limit, precision and accuracy. IOP Conference Series: Materials Science and Engineering, 304, 012001.

Bonetto, R., Castellano, G., & Trincavelli, J. (2001). Optimization of parameters in electron probe microanalysis. X-Ray Spectrometry, 30(5), 313–319.

Carpenter, P. K., & Vicenzi, E. P. (2017). Use of mineral reference standards in EPMA: Instrumental calibration, standards comparison, and quality control. Microscopy and Microanalysis, 23(S1), 496-497.

Donovan, J. J., & Tingle, T. N. (1996). An improved mean atomic number background correction for quantitative microanalysis. Microscopy and Microanalysis, 2(1), 1–7.

Donovan, J. J., Singer, J. W., & Armstrong, J. T. (2016). A new EPMA method for fast trace element analysis in simple matrices. American Mineralogist, 101(8), 1839–1853.

Geller, J. D., & Engle, P. D. (2002). Sample preparation for electron probe microanalysis: Pushing the limits. Journal of Research of the National Institute of Standards and Technology, 107(6), 627–638.

Goldstein, J. I., Newbury, D. E., Michael, J. R., Ritchie, N. W., Scott, J. H., & Joy, D. C. (2017). Scanning electron microscopy and X-ray microanalysis (4th ed.). Springer.

JEOL. (n.d.). EPMA (Electron Probe Microanalyzer). https://th.jeol.com/products/science/epma.php

Reed, S. J. B. (2000). Quantitative trace analysis by wavelength-dispersive EPMA. Mikrochim Acta, 132, 145-151.

Reed, S. J. B. (2005). Electron microprobe analysis and scanning electron microscopy in geology (2nd ed.). Cambridge University Press.

Vaggelli, G., Olmi, F., & Conticelli, S. (1999). Quantitative electron microprobe analysis of reference silicate mineral and glass samples. Acta Vulcanologica, 11(2), 297-303.

Zhao, D., Zhang, Y., & Essene, E. J. (2015). Electron probe microanalysis and microscopy: Principles and applications in characterization of mineral inclusions in chromite from diamond deposit. Ore Geology Reviews, 65(4), 733-748.

Downloads

Published

08-05-2026

How to Cite

Poompuang , S. (2026). The Study of Optimal Conditions for the Quantitative Analysis of Silicate Minerals with Electron Probe Micro Analyzer. CUAST Journal, 15(1), e1320 . retrieved from https://so19.tci-thaijo.org/index.php/CUASTJournal/article/view/1320

Issue

Section

Research Articles

Categories